• Chint Electronic Over Load Relay (EOCR-DS 3) VAYA

    0 out of 5

    Available ampere range (must write in additional information/order notes)

    • 0.5 to 6 Amp
    • 5 to 60 Amp

    Available voltage (write with ampere)

    • 220 V AC
    • 400 V AC
    Rs 5,500.00
  • Electronic Over Load Relay (EOCR-SS)

    5.00 out of 5

    Ampere Range optional: must write any one in additional information/order notes

    • 0.5 to 6.5 Amp
    • 5 to 70 Amp
    Rs 1,900.00
  • EOCR Motor Protection Electronic Over Load Relay upto 120A (OPR-SS3-120) 180v AC-440v AC

    0 out of 5
    Product name: EOCR Motor Protection Electronic Over Load Relay upto 120A (OPR-SS3-120)
    Model: PGOPR SS-SS3
    Manufactured: China
    Usage: Protective
    Theory: Electronic
    Protection: Overcurrent, Underrcurrent, Overvoltage, Undervoltage, Ground Fault
    Current: 0.5A~120A
    Voltage range: 180v AC-440v AC
    Rs 1,600.00
  • EOCR Motor Protection Electronic Over Load Relay upto 60A (OPR-SS3-60) 180v AC-440v AC

    0 out of 5
    Product name: EOCR Motor Protection Electronic Over Load Relay upto 60A (OPR-SS3-60)
    Model: PGOPR SS-SS3
    Manufactured: China
    Usage: Protective
    Theory: Electronic
    Protection: Overcurrent, Underrcurrent, Overvoltage, Undervoltage, Ground Fault
    Current: 0.5A~60A
    Voltage range: 180v AC-440v AC
    Rs 1,600.00
  • LS Thermal Over Load Relay (GTH-22) Pack of 2pcs

    0 out of 5

    Ampere Range (must choose one)

    0.10 to 0.16 Amp

    0.16 to 0.25 Amp

    0.24 to 0.4o Amp

    0.40 to 0.63 Amp

    0.63 to 1.0 Amp

    1.0 to 1.6 Amp

    1.6 to 2.5 Amp

    2.5 to 4.0 Amp

    4 to 6 Amp

    5 to 8 Amp

    6 to 9 Amp

    7 to 10 Amp

    9 to 13 Amp

    12 to 18 Amp

    16 to 22 Amp

    18 to 25 Amp

    22 to 32 Amp

    28 to 40 Amp

    Rs 2,100.00
  • Schneider (LT4706M7A) EOCR Electronic Over Current Relay 0.5~6 A , 200~240 VAC

    0 out of 5

    Model: LT4706M7A

    product or component type
    Electronic over current relay
    device short name
    LT47
    device application
    Protection
    relay application
    Locked rotor, mechanical jamming I > 3 x Isetting
    Sensitivity to phase failure
    Overload Imax > Isetting
    [Us] rated supply voltage
    200…240 V AC
    thermal protection adjustment range
    0.56A
    [Ui] rated insulation voltage
    Power circuit: 600V AC conforming to CSA
    Power circuit: 600V AC conforming to UL
    Power circuit: 690V AC conforming to IEC 60947-4-1
    network frequency
    50…60 Hz
    mounting support
    Rail
    tripping threshold
    0.5…5 A
    electromagnetic compatibility
    Resistance to electrostatic discharge: 8 kV in open air conforming to IEC 61000-4-2
    Resistance to electrostatic discharge: 6 kV in direct mode conforming to IEC 61000-4-2
    Conducted emission: class A conforming to EN 55011
    Immunity to electromagnetic interference: 10 V/m conforming to IEC 61000-4-3
    Immunity to fast transients: 2 kV conforming to IEC 61000-4-4
    Surge withstand: 6 kV conforming to IEC 61000-4-5
    Conducted HF disturbances: 10 V conforming to IEC 61000-4-6
    auxiliary contact composition
    1 NO + 1 NC
    [Ith] conventional free air thermal current
    3A for signalling circuit
    associated fuse rating
    3A gG for signalling circuit
    3A BS for signalling circuit
    [Uimp] rated impulse withstand voltage
    6kV
    time range
    1…120 s – control type R-time
    0.3…30 s – control type O-time
    local signalling
    1 LED (green)
    1 LED (red)
    control type
    automatic: reset
    connections – terminals
    Signalling circuit: screw clamp terminals 1 12.5mm – cable stiffness: flexible with cable end
    Signalling circuit: screw clamp terminals 1 12.5mm – cable stiffness: flexible without cable end
    Signalling circuit: screw clamp terminals 2 12.5mm – cable stiffness: flexible with cable end
    Signalling circuit: screw clamp terminals 2 12.5mm – cable stiffness: flexible without cable end
    tightening torque
    Signalling circuit: 1.7N.m M3.5
    height
    70.3mm
    width
    71mm
    depth
    77.2mm
    net weight
    0.192kg

     

    Rs 13,900.00
  • Schneider (LT4760M7A) EOCR Electronic Over Current Relay 5~60 A , 200~240 VAC

    0 out of 5

    Model: LT4760M7A

    product or component type
    Electronic over current relay
    device short name
    LT47
    device application
    Protection
    relay application
    Overload Imax > Isetting
    Locked rotor, mechanical jamming I > 3 x Isetting
    Sensitivity to phase failure
    [Us] rated supply voltage
    200…240 V AC
    thermal protection adjustment range
    5~60A
    [Ui] rated insulation voltage
    Power circuit: 600V AC conforming to CSA
    Power circuit: 600V AC conforming to UL
    Power circuit: 690V AC conforming to IEC 60947-4-1
    network frequency
    50…60 Hz
    mounting support
    Rail
    tripping threshold
    5…50 A
    electromagnetic compatibility
    Resistance to electrostatic discharge: 8 kV in open air conforming to IEC 61000-4-2
    Resistance to electrostatic discharge: 6 kV in direct mode conforming to IEC 61000-4-2
    Conducted emission: class A conforming to EN 55011
    Immunity to electromagnetic interference: 10 V/m conforming to IEC 61000-4-3
    Immunity to fast transients: 2 kV conforming to IEC 61000-4-4
    Surge withstand: 6 kV conforming to IEC 61000-4-5
    Conducted HF disturbances: 10 V conforming to IEC 61000-4-6
    auxiliary contact composition
    1 NO + 1 NC
    [Ith] conventional free air thermal current
    3A for signalling circuit
    associated fuse rating
    3A gG for signalling circuit
    3A BS for signalling circuit
    [Uimp] rated impulse withstand voltage
    6kV
    time range
    1…120 s – control type R-time
    0.3…30 s – control type O-time
    local signalling
    1 LED (green)
    1 LED (red)
    control type
    automatic: reset
    connections – terminals
    Signalling circuit: screw clamp terminals 1 12.5mm – cable stiffness: flexible with cable end
    Signalling circuit: screw clamp terminals 1 12.5mm – cable stiffness: flexible without cable end
    Signalling circuit: screw clamp terminals 2 12.5mm – cable stiffness: flexible with cable end
    Signalling circuit: screw clamp terminals 2 12.5mm – cable stiffness: flexible without cable end
    tightening torque
    Signalling circuit: 1.7N.m M3.5
    height
    70.3mm
    width
    71mm
    depth
    77.2mm
    net weight
    0.192kg

     

    Rs 14,900.00